MRC:
The primary application for which the item is designed.AAFS
Application Design:
Transmission line
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Brass
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Err-090
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Round, terminal/terminals in opposite surface
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a body surface.ABEM
Body Surface Treatment:
Cadmium plated
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.750 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.688 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.00
MRC:
The total opposition (resistive and reactive) which the item offers to the admittance of an entering flow of alternating current,expressed in ohms.AHTY
Input Impedance Rating In Ohms:
50.0
MRC:
The total opposition /resistive and reactive/ which the output of the item provides to match,for maximum transfer of energy,the input impedance of another item,expressed in ohms.AHTZ
Output Impedance Rating In Ohms:
50.0
MRC:
The amount of electrical energy that can be dissipated.AJDB
Power Rating:
1.0 watts average and 500.0 watts average
MRC:
The decrease in the strength of the radio frequency signals,expressed in decibels.AJDK
Rf Signal Attenuation In Decibels:
10.0
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+0.0/+8.5 gigahertz
MRC:
The minimum and maximum values of the frequency range in which the voltage standing wave ratio is specified.AKNK
Voltage Standing Wave Ratio Frequency Range:
+0.0 to 8.5 gigahertz
MRC:
The frequency at which the attenuation accuracy was measured.ASYE
Attenuation Accuracy Reference Frequency:
8.5 gigahertz
MRC:
The limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.ASYN
Attenuation Accuracy In Decibels:
-0.30/+0.30
MRC:
The limits of permissible variation in the attenuation accuracy from the nominal value at a specified frequency rating or range,expressed in decibels.ASYN
Attenuation Accuracy In Decibels:
-0.30 to 0.30
MRC:
The total variation in attenuation value across the operating frequency range,expressed in decibels.ASZL
Frequency Sensitivity Attenuation In Decibels:
Not rated
MRC:
The specified variation of attenuation caused by a change of temperature,expressed in decibels.ASZM
Temperature Sensitivity Attenuation In Decibels:
0.0001
MRC:
Indicates the type of connection per function.ASZN
Connection Type Per Function:
Male input-output
MRC:
The means of attaching the item.AXGY
Mounting Method:
Connector
MRC:
Indicates the type and number of terminal(s) for providing electrical connection.BBHS
Terminal Type And Quantity:
2 connector
MRC:
The minimum and maximum cyclic changes,per unit of time,for which an item is rated.BNGR
Frequency Range:
Between 0.000 hertz and 8.500 gigahertz