부품 번호 1119808

El Engine Starter Relay-solenoid

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards
부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
1119808
비무장화:
Yes - DEMIL/MLI
수명:
측정 단위:
NIIN:
006407938

부품 정보
Fungus and corrosion resistant

NSN
국가 주식 번호:
2920-00-640-7938 2920006407938
TXT
묘사:
El Engine Starter Relay-solenoid
INC
INC
아이템 이름 코드:
17084
INC
COM
컴플라이언스:
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.281 inches
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
0.344 inches
MRC:
An indication of whether or not an item is capable of operation while submerged.AHZV
Submersibility:
Nonsubmersible
MRC:
The distance between the mounting facilities.ARKQ
Mounting Facility Spacing:
1.750 in. C to c 66 degrees apart on 2.562 in. Radius
MRC:
The nominal value(s) of potential for which the item is rated.AWYG
Voltage Rating:
24.0 volts
MRC:
The amount of current required to activate the item.AXAZ
Pull-in Current:
Between 34.7 amperes and 38.2 amperes
MRC:
The amount of current required to maintain operation of the item.AXBA
Hold-in Current:
6.0 volt-ampere and 6.9 microwatts
MRC:
The measured distance of the plunger stroke.AXBD
Plunger Stroke Length:
0.750 inches
MRC:
An indication of whether or not engaging linkage is included.AXBE
Engaging Linkage:
Not included
MRC:
Designates the thread diameter and number of threads per measurement scale of the accommodated linkage threaded hole.AXBY
Accommodated Linkage Threaded Hole Thread Size:
1/4-20
MRC:
An indication of whether or not the item includes provisions for manually closing the contacts.AXCC
Contact Manual Closing Provision:
Not included
MRC:
The number of control terminals provided.AXCD
Control Terminal Quantity:
2
MRC:
Indicates the type of control terminal/s/ provided.AXCE
Control Terminal Type:
Stud
MRC:
An indication of whether or not a grounded control terminal is included.AXCF
Grounded Control Terminal:
Included
MRC:
The number of main terminals provided.AXHJ
Main Terminal Quantity:
2
MRC:
Indicates the type of main terminal/s/ provided.AXHK
Main Terminal Type:
Stud
MRC:
The diameter of the motor for which the rigid mount is designed.AXHN
Motor Diameter For Which Rigid Mount Is Designed:
5.125 inches
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
4 slot