Engine Generator Regulator
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
3
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Screw
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.195 inches err-100 err-100
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.199 inches err-100 err-100
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
0.195 inches
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
0.750 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the mounting.ADER
Mounting Style:
Two slotted holes, two open slots on a radius
MRC:
An indication of whether or not the item is provided with a self-contained shock mount.AGBC
Shock Mount:
Provided
MRC:
An indication of whether or not shielding against radio interference is provided.ALBH
Radio Interference Shielding:
Not provided
MRC:
The output voltage rating at which the item is designed to operate,expressed in volts.ANPP
Output Voltage Rating In Volts:
12.0
MRC:
The electrical voltage of the system for which the item is designed.ANYC
System Voltage Rating:
12.0
MRC:
Indicates the type of ground the electrical system utilizes.ANYD
System Ground Polarity:
Negative
MRC:
Indicates the type of device used to maintain a constant voltage.ANYE
Voltage Regulator Unit Type:
Wire wound coil
MRC:
The number of individual voltage regulator units contained in the item.ANYH
Voltage Regulator Unit Quantity:
1
MRC:
Indicates the type of device used to limit the current output to the maximum safe value.ANYJ
Current Regulator Unit Type:
Wire wound coil integral w/voltage regulator unit
MRC:
Indicates the type of device used to close and open (break) the circuit.ANYR
Circuit Control Device Type:
Cutout relay
MRC:
An indication of whether or not a reverse current overload circuit breaker is included.ANZB
Reverse Current Overload Circuit Breaker:
Not included
MRC:
An indication of whether or not a field relay unit is included.ANZC
Field Relay Unit:
Included
MRC:
An indication of whether or not the terminal(s) is encased.ANZE
Terminal Encasement:
Not encased
Open Slot Width:
0.195 inches err-100 err-100
Open Slot Width:
0.199 inches err-100 err-100
Open Slot Width:
0.199 inches
Mounting Facility Radius:
2.230 inches
Angle Between Open Slots In Deg:
0.0
Angle Between Slotted Holes In Deg:
0.0