TXT
묘사:
Ignition System Distributor
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Any acceptable
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Rigid coupled
MRC:
Items furnished as accessories which are not specified elsewhere.ABFF
Furnished Items:
Distributor
MRC:
A measurement taken at right angles to the length of the mounting slot,in distinction from thickness.ABTD
Mounting Slot Width:
Between 0.156 inches and 0.158 inches
MRC:
A measurement of the longest dimension of the mounting slot,in distinction from width.ABVG
Mounting Slot Length:
Between 0.495 inches and 0.505 inches
MRC:
A measurement of the longest dimension of the shaft,in distinction from width.ABXF
Shaft Length:
Between 3.226 inches and 3.295 inches
MRC:
The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
Environmental Protection:
High altitude
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Plain
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
1
MRC:
An indication of whether or not a distributor cap is included.ARFE
Distributor Cap:
Included
MRC:
The means of attaching the item.AXGY
Mounting Method:
Base
MRC:
The number of impulses produced by one complete revolution.AXRT
Impulse Quantity Per Revolution:
6
MRC:
Indicates the type of ignition for which the item is designed.AXRW
Ignition Type For Which Designed:
Single
MRC:
Indicates the type of terminals included in the distributor cap to accommodate the spark plug wires.AYEN
Secondary Terminal Type:
Push-in
MRC:
Indicates the type of terminals included in the distributor cap to accommodate the coil wire.AYER
Coil Terminal Type:
Push-in
MRC:
Indicates the type of primary terminal accommodation/s/ on the item.AYEY
Primary Terminal Accommodation Type:
Stud
MRC:
The means by which the spark advance is controlled.AYKD
Spark Advance Control Method:
Manual
MRC:
The maximum number of degrees the item is advanced.AYKF
Maximum Advance Deg:
30.0
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Slot
MRC:
A designation indicating the diameter-pitch combination and the number of threads per measurement scale applied to a series of diameters of a primary terminal accommodation.BYPP
Primary Terminal Accommodation Thread Series:
Unc
MRC:
The means by which the spark is transferred from the rotor to the spark plug terminals.CPWB
Spark Distribution Method:
Contact
MRC:
A measurement of the length of a straight line which passes through the center of a coaxial cylinder in plan view which would bound the crest of an external thread or the root of an internal thread.CPWH
Primary Terminal Accommodation Thread Diameter:
0.164 inches
MRC:
The number of screw threads on the primary terminal accommodation per linear inch,including incomplete threads,on a line parallel to the thread axis.CPWJ
Primary Terminal Accommodation Thready Qty Per Inch (tpi):
32
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects a surface.SURF
Surface Treatment:
Any acceptable