MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
0.725 millihenries single component 1st winding and 1.09 millihenries single component 1st winding
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
2.89 millihenries single component 2nd winding and 4.34 millihenries single component 2nd winding
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
100.0 kilohertz single component
MRC:
The designation describing the method used in forming the core.ACZR
Core Construction:
S0lid single component
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
0.600 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.200 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
120.0 degrees celsius
MRC:
The number of individual /not electrically connected/ windings.AKDX
Winding Quantity:
2 single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Fully enclosed
MRC:
The means of attaching the item.AXGY
Mounting Method:
Terminal single group
MRC:
The means by which the rating is determined.BKPL
Rating Method:
Electrical single component all winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
2.5 amperes dc single component 1st winding
MRC:
The amount of operating current for which the winding is designed.CRBZ
Winding Operating Current:
500.0 milliamperes dc single component 2nd winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
0.380 single component 1st winding
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
1.280 single component 2nd winding
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
17.00 ac pounds per hour wet single component 1st winding
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
31.00 ac pounds per hour wet single component 2nd winding
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
16340-11-00094 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
4 wire lead