MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Rectangular
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
2.500 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
0.500 inches
MRC:
The number of individual sections included in the item.AFBH
Individual Section Quantity:
1
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
800.000 volts
MRC:
The total oppositon (resistive and reactive) which the item offers to the input flow of alternating current.ANSL
Input Impedance Rating:
100.000 ohms
MRC:
The total opposition (resistive and reactive) which the item offers to the output flow of alternating current.ANSR
Output Impedance Rating:
100.000 ohms
MRC:
A measurement between specified points on a body in distinction from height.ARBR
Body Depth:
0.500 inches
MRC:
The facility for mounting the item.AZGM
Mounting Facility:
Terminal
MRC:
The means used to vary the delay time of the item.CCDN
Delay Time Variation Method:
Tapped
MRC:
The time delay of each section of an item.CCDQ
Section Delay Time:
200.000 milliseconds single section
MRC:
The number of segments into which a section is divided.CCDR
Segment Quantity Per Section:
9 single section
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.040 milliseconds single section 2nd segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.020 milliseconds single section 1st segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.080 milliseconds single section 4th segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.060 milliseconds single section 3rd segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
100.000 milliseconds single section 5th segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
120.000 milliseconds single section 6th segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
140.000 milliseconds single section 7th segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
160.000 milliseconds single section 8th segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
180.000 milliseconds single section 9th segment err-100
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.080 milliseconds single section 4th segment
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
0.040 milliseconds single section 2nd segment
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
120.000 milliseconds single section 6th segment
MRC:
The time delay of each segment.CCDS
Segment Delay Time:
180.000 milliseconds single section 9th segment
MRC:
The rated time required for the pulse to rise.CCDX
Pulse Rise Time Rating:
0.040 milliseconds
MRC:
Indicates the type and number of terminals for providing electrical connection.CCFF
Terminal Type And Quantity:
15 wire leads