부품 번호:
10a4656sxbmbecx0-4.25gpm
부품 정보
Actual maximum water capacity is 4.25 gpm; packing gland type pressure seals; maximum working pressure @ 100 degrees f: 200 psig; ambient temperature range: 32 degrees f to 140 degrees f
TXT
묘사:
Flow Rate Indicating Meter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.188 inches
MRC:
A narrative description of the type of inlet connection.ACQW
Inlet Connection Type:
Flange
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Los angeles class ssn (688)
MRC:
An indication of whether or not an integral safety device is included.AHZU
Integral Relief Valve:
Not included
MRC:
An indication of the type of meter.ANTH
Meter Type:
Float
MRC:
Indicates the design type of the item.APGF
Design Type:
Glass
MRC:
Indicates the type of unit.APQB
Unit Type:
Mounted
MRC:
The number of scales on the item.APSJ
Scale Quantity:
1
MRC:
A narrative description of the type of outlet connection.ARTH
Outlet Connection Type:
Flange
MRC:
The number of floats provided.AWAE
Float Quantity:
1
MRC:
The element,compound,or mixture of which the tube is fabricated,excluding any surface treatment.AWGJ
Tube Material:
Glass
MRC:
The means of attaching the item.AXGY
Mounting Method:
Direct line
MRC:
The minimum and maximum markings on a dial scale.BHBY
Dial Scale Marking Range:
+0.0/+4.3
MRC:
Indicates the type of float used.BHSQ
Float Type:
Free
MRC:
The element,compound,or mixture of which the float is fabricated,excluding any surface treatment.BJDM
Float Material:
Steel, stainless
MRC:
An indication of whether or not an integral heat source is included.BNHN
Integral Heat Source:
Not included
MRC:
The number of metering tubes provided.CPZF
Metering Tube Quantity:
1
MRC:
The maximum amount of water for which the item is rated,expressed in gallons per minute.CPZG
Maximum Water Capacity In Gallons Per Minute:
4.3
MRC:
An indication of whether or not a dial scale reference pointer is included.CPZK
Dial Scale Reference Pointer:
Included
MRC:
An indication of whether or not a spinning float is included.CPZM
Spinning Float:
Not included
MRC:
An indication of whether or not an integral pulsation dampener is included.CPZN
Integral Pulsation Dampener:
Not included
MRC:
The inlet connection position for which the item is designed.CPZP
Inlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of inlet connection device provided.CPZQ
Inlet Connection Device Type:
Stationary
MRC:
The outlet connection position for which the item is designed.CPZR
Outlet Connection Position For Which Designed:
Horizontal
MRC:
Indicates the type of outlet connection device provided.CPZS
Outlet Connection Device Type:
Stationary
MRC:
An indication of whether or not an alarm signal is included.CPZT
Alarm Signal:
Not included