TXT
묘사:
Saturable Reactor
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
2.987 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
2.625 inches single mounting facility single center group
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
2.125 inches single mounting facility single center group
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
6.094 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
3.512 inches
MRC:
The number of complete cyclic changes,per unit of time,for which an item is rated.ACZB
Frequency Rating:
60.0 hertz single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Hermetically sealed
MRC:
The number of mounting facilities provided.AKPV
Mounting Facility Quantity:
4 single group
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded stud single group
MRC:
The purpose and the total number of individual (not electrically connected) windings designed to perform in a transformer.BPLC
Winding Function And Quantity:
2 primary single component and 3 control single component
MRC:
The amount of control current beyond which an increase in control current produces no increase in the items output.CHTZ
Saturation Current Rating:
570.0 milliamperes
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
1.200 single component 3rd control
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
120.000 single component 1st control
MRC:
The opposition to the flow of direct current offered by an item,expressed in ohms.CRGS
Dc Resistance Rating In Ohms:
40.000 single component 2nd control
MRC:
The value/s/ of the operating voltage applied to the winding.CWJS
Winding Operating Voltage:
30.00 ac pounds per hour with retaining chain single component all primary
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
11 solder stud