부품 번호 10937022

Box Switch

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 103.06 and 139.131 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
10937022
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
001793443
NSN
국가 주식 번호:
5930-00-179-3443 5930001793443
TXT
묘사:
Box Switch
INC
INC
아이템 이름 코드:
02636
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
With side operator
MRC:
The specific commercial rating which classes the item as to what degree the item will withstand environmental elements and/or hazardous locations.ABFE
Hazardous Locations/environmental Protection:
Dustproof
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the length.ABKQ
Center To Center Distance Between Mounting Facilities Parallel To Length:
8.500 inches
MRC:
The distance between the center of one mounting facility and the center of the adjacent mounting facility parallel to the width.ABKR
Center To Center Distance Between Mounting Facilities Parallel To Width:
5.188 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
11.000 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
7.625 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
4.875 inches
MRC:
The maximum voltage rating at which the item is designed to operate in an alternating current and/or direct current circuit,expressed in volts.AFXE
Maximum Voltage Rating In Volts:
240.0 ac
MRC:
The means of attaching the item.AXGY
Mounting Method:
Panel
MRC:
The designation that identifies the electrical configuration of a nonpile-up contact group including the number of switching poles or forms.CRLD
Nonpile-up Contact Arrangement:
1 pole, single throw, both positions maintained single switch unit
MRC:
The amount of current the contacts are rated to make or break at maximum rated voltage,with a specified load.CXQR
Contact Load Current Rating At Maximum Rated Voltage:
2.000 amperes resistive ac
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 screw

{lang[cimilar]} Box Switches

« Switches {lang[catalog]}
지금 비교»
맑다 | 숨기다