MRC:
The ability of an item to withstand a specified torque load without fracture.AAPL
Torque Load Rating:
117.3 inch-pounds
MRC:
The length of a straight line which passes through the center of the smallest cross section of a spline,and terminates at the circumference.AAUH
Spline Minor Diameter:
Between 1.049 inches and 1.062 inches
MRC:
The length of a straight line which passes through the center of the largest cross section of a spline,and terminates at the circumference.AAUJ
Spline Major Diameter:
Between 1.247 inches and 1.248 inches
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Flange
MRC:
The number of splines on or in the item.ABSA
Spline Quantity:
12
MRC:
The number of bolt holes provided on the item.AECS
Bolt Hole Quantity:
8
MRC:
A measurement indicating the diameter-pitch per specific measurement scale of the item.AGJS
Pitch Diameter:
1.167 inches
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Splined, involute external
MRC:
The direction of rotation of a rotating shaft as viewed from the drive end.AKCT
Shaft Rotation Direction:
Clockwise and counterclockwise
MRC:
A measurement of the longest dimension the shaft extends from the item.ARQA
Shaft Protrusion Length:
2.000 inches
MRC:
A measurement of the spline pitch of the item.ASAP
Spline Pitch:
12/24
MRC:
The number of connections furnished.ASMM
Connection Quantity:
2
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Inlet
MRC:
The maximum rated working pressure of an item at a specified temperature range.AXFB
Maximum Working Pressure Rating At Specificationified Tempurature Range:
2000psi at minus 65 degrees f to plus170 degrees f
MRC:
The design of the connection.AXFC
Connection Design:
Flanged
MRC:
Designates the thread diameter and number of threads per measurement scale of the bolt hole.AXFD
Bolt Hole Thread Size:
0.500-13
MRC:
The pressure angle of the spline,expressed in degrees.AXFG
Spline Pressure Angle In Deg:
30.0
MRC:
A measurement of the longest dimension of a spline,in distinction from width.AXFH
Spline Length:
1.875 inches
MRC:
Indicates the displacement type.AXFP
Displacement Type:
Constant
MRC:
The spacing in the arrangement of the bolt holes.AZFF
Bolt Hole Spacing:
1-13/32 in. By 2-3/4 in. 2 places
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off.AZFH
Housing Surface Treatment:
Enameled