TXT
묘사:
Fluid Pressure Regulating Valve
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Air
MRC:
A narrative description of the type of end connection.ACKM
First End Connection Type:
Plain face flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACKN
First End Style Designator:
Plain
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the end flange.ACKT
First End Flange Shape Style:
Octagon w/ bolt holes
MRC:
A measurement of the longest dimension of the first end flange, in distinction from width.ACKV
First End Flange Length:
2.370 inches
MRC:
A measurement taken at right angles to the length of the first end flange, in distinction from thickness.ACKW
First End Flange Width:
2.370 inches
MRC:
The number of bolt holes provided on the item.ACKZ
First End Bolt Hole Quantity:
4
MRC:
The length of a straight line which passes through the center of a bolt hole,and terminates at the circumference.ACLA
First End Bolt Hole Diameter:
0.281 inches
MRC:
The part that controls the flow through the item.ADQU
Flow Control Device:
Disk, circular
MRC:
Indicates the basic design type used for regulating the item.AEVN
Regulation Type:
Automatic single stage
MRC:
The means of providing resistance to the media passing through a valve,whereby the valve is actuated to regulate the flow.AEVR
Valve Loading Method:
Spring
MRC:
The maximum pressure of the media on the inlet side at which an item is designed to operate.AEVZ
Maximum Inlet Pressure Rating:
160.0 pounds per square inch
First End Center To Center Distance Between Holes Along Length:
1.812 inches
First End Center To Center Distance Between Holes Along Width:
1.812 inches
MRC:
A value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.AZKQ
Tempurature Rating:
Between -65.0 degrees fahrenheit and 400.0 degrees fahrenheit