TXT
묘사:
Waveguide Assembly
MRC:
The style designation indicating the configuration that most nearly corresponds to the cross-sectional shape of the item.AAGR
Cross Sectional Shape:
Internal, rectangular external, rectangular
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
2b first flange all connection facilities
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand first flange all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the construction of the tubing wall.AHRV
Tubing Wall Construction Style:
Seamless single tubing segment
MRC:
The number of flanges provided with the item.AHSF
Flange Quantity:
2
Flange Inside Width:
0.705 inches second flange and 0.707 inches second flange
Flange Inside Width:
0.705 inches and 0.707 inches second flange
Flange Inside Height:
0.309 inches first flange and 0.313 inches first flange
Flange Inside Height:
0.394 inches second flange and 0.396 inches second flange
Flange Inside Height:
0.309 inches and 0.313 inches first flange
Flange Inside Height:
0.394 inches and 0.396 inches second flange
Flange Outside Width:
1.297 inches first flange and 1.327 inches first flange
Flange Outside Width:
1.298 inches second flange and 1.328 inches second flange
Flange Outside Width:
1.297 inches and 1.327 inches first flange
Flange Outside Width:
1.298 inches and 1.328 inches second flange
Flange Outside Height:
1.297 inches first flange and 1.327 inches first flange
Flange Outside Height:
1.298 inches second flange and 1.328 inches second flange
Flange Outside Height:
1.298 inches and 1.328 inches second flange
Flange Outside Height:
1.297 inches and 1.327 inches first flange
Flange Inside Diameter:
0.620 inches first flange and 0.624 inches first flange
Flange Inside Diameter:
0.620 inches and 0.624 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.298 inches second flange and 0.328 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.360 inches first flange and 0.390 inches first flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.298 inches and 0.328 inches second flange
MRC:
A measurement between specified points on the flange,in distinction from height.AHTD
Flange Depth:
0.360 inches and 0.390 inches first flange
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.144 inches second flange all connection facilities and 0.147 inches second flange all connection facilities
MRC:
The length of a straight line which passes through the center of a flange connecting hole,and terminates at the circumference.AHTN
Flange Connecting Hole Diameter:
0.144 inches and 0.147 inches second flange all connection facilities
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.12
MRC:
The difference in the amount of energy available before and after the insertion of an apparatus in a transmission system,expressed in decibels.AHTX
Insertion Loss In Decibels:
0.20
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
30.0 pounds per square inch gage
Waveguide Outside Width:
Between 0.699 inches and 0.705 inches
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches first flange all connection facilities
Waveguide Inside Width:
Between 0.620 inches and 0.625 inches
Waveguide Inside Height:
Between 0.309 inches and 0.314 inches
Waveguide Outside Height:
Between 0.388 inches and 0.394 inches
Waveguide Longer Offset Distance:
3.900 inches
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 threaded hole first flange all connection facilities
MRC:
The type and number of facilities by which the flange is connected.CSQT
Flange Connecting Facility And Quantity:
4 unthreaded hole second flange all connection facilities
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Choke type first flange
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the flange.CTCJ
Flange Style:
Cover type second flange
Waveguide Offset Distance:
3.840 inches
MRC:
Flexible,capable of being bent,turned or twisted,within limits,without breaking,or rigid,resisting change of form,inflexible.FLEX
Flexibility:
Flexible single tubing segment
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy all tubing segment and flange
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Rubber synthetic single tubing jacket
MRC:
An indication of the precious material and its location in the item.PMLC
Precious Material And Location:
Internal surfaces silver
MRC:
Identification of the precious material contained in the item.PRMT
Precious Material:
Silver
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Silver all tubing segment and flange inside surfaces
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Bend type
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc first flange all connection facilities
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment