부품 번호 10654-1T021

Liquid Storage Tank

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 129103 and 168827 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
10654-1t021
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
005425894
NSN
국가 주식 번호:
5430-00-542-5894 5430005425894
TXT
묘사:
Liquid Storage Tank
INC
INC
아이템 이름 코드:
36423
MRC:
Consists of plating,dip,and/or coating that cannot be wiped off. plating and/or coating is any chemical and/or metallic additive,electrochemical,or mild mechanical process which protects the outside surface.AAJP
Outside Surface Treatment:
Paint
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the inside circumference.AARX
Inside Diameter:
24.000 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
32.250 feet
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
110.000 feet
MRC:
The element,compound,or mixture of which the shell is fabricated.AEUG
Shell Material:
Steel
MRC:
The means by which the body parts are designed to be fastened together.AFPN
Assembly Method:
Welded
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
1 automatic tank gage; 10 low neck inspection hatches; 1 drain assembly; 1 pressure relief vent; 1 vent pipe
MRC:
The form of assembly in which the item is supplied.ALPM
Assembly Form:
Knocked-down
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Vertical
MRC:
An indication of whether or not a mounting bracket is provided.AQFN
Mounting Bracket:
Not provided
MRC:
An indication of whether or not a fitting(s) is included.AYNB
Fitting:
Not included
MRC:
Indicates the location for which the item is designed to be installed.AYNY
Installation Location:
Above ground
MRC:
The physical configuration of the top of the item.BBYK
Top Shape:
Conical
MRC:
The element,compound,or mixture of which the top is fabricated,excluding any surface treatment.BDXC
Top Material:
Steel
MRC:
Indicates the capacity of the tank.BSSM
Tank Capacity:
2100000.0 gallon, us measure
MRC:
The liquid for which the item is designed.BXHJ
Liquid For Which Designed:
Petroleum product
MRC:
The physical configuration of the bottom of the item.BZKX
Bottom Shape:
Flat
MRC:
Indicates the type of weld provided.CBPQ
Weld Type:
Butt or lap
MRC:
A measurement of the smallest dimension of the shell material,in distinction from length or width.CBPS
Shell Material Thickness:
0.2500 inches
MRC:
A measurement of the smallest dimension of the shell material,in distinction from length or width.CBPS
Shell Material Thickness:
0.3700 inches
MRC:
A measurement of the smallest dimension of the shell material,in distinction from length or width.CBPS
Shell Material Thickness:
0.5000 inches
MRC:
The element,compound,or mixture of which the bottom is fabricated,excluding any surface treatment.CBPY
Bottom Material:
Steel
MRC:
A measurement of the smallest dimension of the bottom material,in distinction from length or width.CBPZ
Bottom Material Thickness:
0.250 inches
MRC:
An indication of whether or not a top is included.CBQB
Top:
Included
MRC:
A measurement of the smallest dimension of the top material,in distinction from length or width.CBQC
Top Material Thickness:
0.1875 inches
MRC:
Indicates the type and number of manholes provided.CBQF
Err Default:
Err default
MRC:
Indicates the type and number of manholes provided.CBQF
Manhole Type And Quantity:
2 dome
MRC:
The means of attaching the manhole.CBQG
Err Default:
Err default
MRC:
The means of attaching the manhole.CBQG
Manhole Mounting Method:
Bolt
MRC:
Indicates the location of the manhole.CBQH
Err Default:
Err default
MRC:
Indicates the location of the manhole.CBQH
Manhole Location:
1 located in center of top and other located on shell adjacent to bottom
MRC:
The physical configuration of the manhole.CBQJ
Err Default:
Err default
MRC:
The physical configuration of the manhole.CBQJ
Manhole Shape:
Round
MRC:
Indicates the type of cleanout provided on the item.CBQK
Err Default:
Err default
MRC:
Indicates the type of cleanout provided on the item.CBQK
Cleanout Type:
Flush
MRC:
Indicates the location of the cleanout.CBQL
Err Default:
Err default
MRC:
Indicates the location of the cleanout.CBQL
Cleanout Location:
In shell and adjacent to the bottom
MRC:
The physical configuration of the cleanout.CBQM
Err Default:
Err default
MRC:
The physical configuration of the cleanout.CBQM
Cleanout Shape:
Rectangular
MRC:
An inside measurement from the bottom to the top of the item,in distinction from depth.CCLP
Err Default:
Err default
MRC:
An inside measurement from the bottom to the top of the item,in distinction from depth.CCLP
Cleanout Inside Height:
36.000 inches
MRC:
An inside measurement taken at right angles to the length of a cleanout,in distinction from thickness.CCLQ
Err Default:
Err default
MRC:
An inside measurement taken at right angles to the length of a cleanout,in distinction from thickness.CCLQ
Cleanout Inside Width:
48.000 inches
MRC:
The number of fitting openings provided.CCLW
Fitting Opening Quantity:
1
MRC:
The number of fitting openings provided.CCLW
Fitting Opening Quantity:
10
MRC:
The number of fitting openings provided.CCLW
Fitting Opening Quantity:
2
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 19th opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 2nd opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 3rd opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 5th opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 6th opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 7th opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 8th opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Unthreaded 9th opening
MRC:
An indication of whether the fitting opening is threaded.CCLX
Fitting Opening Thread Provision:
Err-070
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
12.000 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
2.000 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
20.000 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
21.000 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
24.000 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
3.000 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
3.750 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
4.000 inches
MRC:
The length of a straight line which passes through the center of a fitting,and terminates at the circumference.CCLY
Fitting Opening Diameter:
8.000 inches
MRC:
Indicates the location of the fitting opening.CCLZ
Err Default:
Err default
MRC:
Indicates the location of the fitting opening.CCLZ
Fitting Opening Location:
Located on lower tier of shell; lower tier of shell; lower tier of shell; top of tank; top of tank; top of tank; top of tank; top of tank; top of tank; top of tank
MRC:
Indicates the location of the ladder.CCMB
Err Default:
Err default
MRC:
Indicates the location of the ladder.CCMB
Ladder Location:
Exterior
MRC:
The physical configuration of the item.SHPE
Shape:
Cylindrical
MRC:
The number,letter,or symbol that indicates the type,style,grade,class,and the like,of an item in a nonidentifying specification or standard.ZZZT
Specification Or Standard:
2 type

{lang[cimilar]} Liquid Storage Tanks

« Storage Tanks {lang[catalog]}
지금 비교»
맑다 | 숨기다