TXT
묘사:
Transmitter Synchro
MRC:
The basic material of which the body is fabricated.AAFZ
Body Material:
Steel, stainless
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
0.8900 inches
MRC:
The length of a straight line which passes through the center of a flange,and terminates at the circumference.ABKK
Flange Diameter:
Between 1.5620 inches and 1.5624 inches
MRC:
The length of a straight line which passes through the center of the body,and terminates at the circumference.ABPM
Body Diameter:
Between 1.4300 inches and 1.4350 inches
MRC:
The measure of sensitivity of the item to be packaged. a factor used by packaging engineers in devising proper cushioning in a package.AFJN
Fragility Factor:
Moderately rugged
MRC:
An alpha and/or numeric designation indicating the size by which the body is identified.AJSL
Body Size:
16
MRC:
The value of the primary excitation voltage for which the rotor is rated,expressed in volts.AJSR
Rotor Input Voltage Rating In Volts:
115.0
MRC:
The cycles per second /hertz/ of the alternating current.AJSS
Frequency In Hertz:
400.0
MRC:
The value of the primary excitation current for which the rotor is rated,with stator /secondary/ circuit open.AJST
Rotor Input Current Rating:
70.0 milliamperes
MRC:
The value of the primary /electrical/ excitation power for which the rotor is rated.AJSV
Rotor Input Electrical Power Rating:
2.5 watts
MRC:
Indicates the location of the terminal/s/ on the item.CQTM
Terminal Location:
Rear
Body Thru-hole Diameter:
Between 0.1230 inches and 0.1232 inches
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-milstd202 standard (includes industry or association standards, individual manufactureer standards, etc.).
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
5 wire lead