TXT
묘사:
Liquid Sight Indicator
MRC:
The distance between mounting facility centers.AEJN
Distance Between Mounting Facility Centers:
24.000 inches
MRC:
The length of a straight line which passes through the center of the tube for which designed,and terminates at the outside circumference.ASPP
Tube Outside Diameter For Which Designed:
0.750 inches both ends
MRC:
The maximum value which expresses the degree of heat or cold as applied to the operation,or limitation of operation,of an item.ATQZ
Maximum Tempurature Rating:
300.0 degrees fahrenheit
MRC:
Indicates the type of end connection.AWZY
End Connection Type:
Flanged, plain both ends
MRC:
The maximum working pressure at which an item is designed to operate.BPHD
Maximum Working Pressure:
450.0 pounds per square inch
MRC:
Indicates the information designed to be visibly shown.CSQG
Furnished Data:
Liquid level
MRC:
The method or component used to visibly show the information required.CTCY
Data Furnishing Method:
Clear window
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Copper alloy
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Water
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Gage valve