TXT
묘사:
Film Fixed Resistor
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-10.0/+10.0 second temp coefficient
MRC:
A constant that represents the proportionate change in resistance caused by a change in temperature,expressed in parts per million change per degree celsius.AAPE
Tempurature Coefficient Of Resistance In Ppm Per Deg Celsius:
-5.0/+5.0 first temp coefficient
MRC:
A measure of the opposition to the flow of electrical current.AAPP
Electrical Resistance:
8.000 kilohms
MRC:
The limits of permissible variation in the electrical resistance value of an item from its rated value,expressed in percent.AAPQ
Resistance Tolerance In Percent:
-0.100/+0.100
MRC:
The ambient temperature of the medium surrounding an item at which it can be operated continuously at full rated power,expressed in degrees celsius.AAQF
Ambient Tempurature In Deg Celsius At Full Rated Power:
125.0
MRC:
The ambient temperature at which the power dissipation of an item is operated to zero percent of the full rated power,expressed in degrees celsius.AAQG
Ambient Tempurature In Deg Celsius At Zero Percent Rated Power:
175.0
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
+125.0/+175.0 temp range of second temp coefficient
MRC:
The maximum and minimum temperatures to which the temperature coefficient applies,expressed in degrees celsius.AAQH
Tempurature Range Of Tempurature Coefficient In Deg Celsius:
-55.0/+125.0 temp range of first temp coefficient
MRC:
The means provided to coat,cover,or protect the item.AAQZ
Inclosure Method:
Encapsulated
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
Indicates the type designator,per mil-std-1276,of the detail requirements of leads used on electronic components.AARF
Mil-std-1276 Wire Lead Type Designator:
C
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Established
MRC:
The rate of failure determined under specified conditions to establish the reliability of an item,expressed in percent.AARH
Reliability Failure Rate Level In Percent:
0.010
MRC:
A measurement of the longest dimension of a terminal,in distinction from width.ABJT
Terminal Length:
Between 1.375 inches and 1.625 inches
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 0.290 inches and 0.320 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 0.295 inches and 0.345 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 0.095 inches and 0.120 inches
MRC:
The maximum amount of electrical energy that can be expended by an item,expressed in watts.AEFB
Power Dissipation Rating In Watts:
0.300 free air
MRC:
A measurement of volume taken by multiplying the length by the width by the height of an item and rendered in cubic units.CBME
Cubic Measure (non-core):
0.011 cubic inches
MRC:
The measured weight of an item unencumbered by packaging or packing material.PKWT
Unpackaged Unit Weight:
1.0 grams
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Terminals one edge
MRC:
The specification,standard,drawing,or similar instrument that specifies environmental and performance requirements or test conditions under which an item is tested and establishes acceptable limits within which the item must conform identified by an alphabetic and/or numeric reference number. includes the commercial and government entity (cage) code of the entity controlling the instrument.TEST
Test Data Document:
81349-mil-r-55182 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
MRC:
The document designator of the specification or standard which established the item of supply.ZZZK
Specification Data:
81349-mil-r-55182/9 government specification