부품 정보
Cast beryllium copper water jacket; waveguide and flange copper; fittings cres class 303; chromate and paint; do not paint flange face or fitting threads
TXT
묘사:
Electrical Dummy Load
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.531 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
2.750 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 1.933 inches and 1.943 inches
MRC:
The ratio of the maximum to the minimum amplitude of pressure /voltage/ measured along the path of the waves.AHTW
Voltage Standing Wave Ratio:
1.08
MRC:
Indicates the type of facility provided on the device for attaching to another item.AKRZ
Termination Type:
Connection coaxial and waveguide flange
MRC:
The location of the threads on the intake connection.AKSC
Intake Connection Thread Location:
External
MRC:
The position in which the item is designed to operate.ARNH
Operating Position:
All positions
MRC:
The nominal exerted outward force,per unit of area,for which the item is designed.AWNC
Internal Operating Pressure:
15.0 pounds per square inch gage
MRC:
An indication of whether or not a feature is included for rf connector changing.AWPB
Rf Connector Changing Feature:
Included
MRC:
The means of cooling used to maintain the required operating temperature of the item.BFMF
Cooling Method:
Self-cooled
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Waveguide mounted
MRC:
The justification for the assignment of a federal supply class /fsc/ to an item based on the classification of the next higher classifiable assembly.ZZZV
Fsc Application Data:
Antennas, waveguides, and related equipment