부품 정보
Outside air temperature sensor
TXT
묘사:
Ambient Temperature Sensor
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
3.040 inches
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
2.490 inches
MRC:
The minimum and maximum limits of temperature at which the item is rated for operation.AFGA
Operating Tempurature Range:
-65.0/+85.0 degrees celsius
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
7
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
Transport aircraft, cn-235
MRC:
The recognized shape,configuration,structure,or mold of a substance,natural or refined,that most nearly corresponds to the appearance of the item.AGXW
Physical Form:
Rectangular
MRC:
Indicates the type of operation by which the item is controlled.BSXS
Operation Type:
Direct
MRC:
Those unusual or unique characteristics or qualities of an item not covered in the other requirements and which are determined to be essential for identification.FEAT
Special Features:
Flight operating ranges - altitude minus 1000.0 to 60000.0 feet; speed mach 0.0 to 0.6; temperature exposure minus 70.0 to plus 250.0 degrees c; mounting flange - 6 through holes 0.170 inch diameter on 2.000 inch diameter bolt circle; single 500.0 ohm element; mating bayonet connector nsn 5935007798607 or equivalent