TXT
				
				
					묘사:
				
				
					Radio Frequency Interfere Filter				
			 
			
										
					
						MRC:
						The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
					 
					
						Overall Length:
					
					
						3.359 inches 					
				 
							
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						3.342 inches 					
				 
							
					
						MRC:
						A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
					 
					
						Body Width:
					
					
						0.844 inches 					
				 
							
					
						MRC:
						A measurement from the bottom to the top of the body,in distinction from depth.ADAU
					 
					
						Body Height:
					
					
						2.842 inches 					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 1st radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 5th radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 3rd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a source of energy to the input terminals of an item.AHAQ
					 
					
						Source Impedance Rating Per Function:
					
					
						50.0 ohms 4th radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 1st radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 3rd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 2nd radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 4th radio interference					
				 
							
					
						MRC:
						The total opposition per function,presented by a load to the output terminals of an item.AHAS
					 
					
						Load Impedance Per Function:
					
					
						50.0 ohms 5th radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 1st radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 2nd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 3rd radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 4th radio interference					
				 
							
					
						MRC:
						The cycles per second /hertz/ of the power line alternating current.AHBB
					 
					
						Power Line Frequency Rating Per Function In Hertz:
					
					
						400.0 5th radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						2.5 1st radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						2.5 3rd radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						2.5 4th radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						2.5 5th radio interference					
				 
							
					
						MRC:
						The level of electrical flow,per function,for which the item is designed to operate,expressed in ampers.AHBC
					 
					
						Operating Current Rating Per Function In Amps:
					
					
						2.5 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 1st radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 2nd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 4th radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 3rd radio interference					
				 
							
					
						MRC:
						Indicates the type of principal circuitry per function interconnected within the item to produce the desired frequency versus attenuation characteristics.AHBL
					 
					
						Principal Circuitry Type Per Function:
					
					
						Inductance-capacitance 5th radio interference					
				 
							
					
					
						Distance Between Mounting Surface And Lower End:
					
					
						1.781 inches 					
				 
							
					
						MRC:
						A designation distinguishing one group of screw thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter on the mounting facility.AKEJ
					 
					
						Mounting Facility Screw Thread Series Designator:
					
					
						Unef					
				 
							
					
						MRC:
						Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
					 
					
						Inclosure Type:
					
					
						Hermetically sealed					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						1 threaded bushing					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 connector,  receptacle input 1st function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						1 tab,  solder lug ground 3rd function					
				 
							
					
						MRC:
						Indicates the functional type and number of terminals providing electrical connection to the item.CQDW
					 
					
						Functional Terminal Type And Quantity:
					
					
						5 tab,  solder lug output 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 1st radio interference 1st function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 2nd radio interference 2nd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 3rd radio interference 3rd function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 4th radio interference 4th function					
				 
							
					
						MRC:
						The level of electrical potential and type of current,per function,for which the item is designed.CQGC
					 
					
						Operating Voltage Rating And Type Per Function:
					
					
						115.0 volts ac 5th radio interference 5th function					
				 
							
					
						MRC:
						A designation that is used for the purpose of general identification of the thread.CQJX
					 
					
						Thread Size:
					
					
						1.250 inches					
				 
							
					
						MRC:
						The chemical compound or mechanical mixture properties of which the body is fabricated.CQRG
					 
					
						Body Material:
					
					
						Metal					
				 
							
					
						MRC:
						The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
					 
					
						Style Designator:
					
					
						Rectangular terminal/terminals on opposite surfaces