부품 정보
Consists of power supply p/n lt-804 nsn 6130-01-288-2491 q type 2; p/n lra-17-cs rack adaptor with chassis slides q type 1
TXT
묘사:
Power Supply Assembly
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
21.125 inches
MRC:
The distance measured in a straight line from the bottom to the top of an item.ABKW
Overall Height:
5.219 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
19.000 inches
MRC:
The national stock number or the identification information of the end equipment for which the item is a part.AGAV
End Application:
AN/M-PQ-T3;-E/I6
MRC:
The relationship of the electrical power source to the item.AKWC
Electrical Power Source Relationship:
Operating
MRC:
Indicates the type of power unit included with the item.AMKG
Power Unit Type:
Silicon controlled rectifier single operating power rqmt
MRC:
The installation for which the item is designed.AMQY
Installation Design:
Slide support
MRC:
The number of input alternating current phase(s).ANPM
Input Phase:
Single single operating power rqmt
MRC:
The input value/s/,or range of values,for which the item is rated.APNX
Input Voltage Rating:
187.0 ac pounds per hour dry single operating power rqmt and 242.0 ac pounds per hour with retaining chain single operating power rqmt
MRC:
The output value/s/,or range of values,for which the item is rated.APPA
Output Voltage Rating:
0.0 dc volts multiple power outputs w/identical ratings and 60.0 dc volts multiple power outputs w/identical ratings
MRC:
The number of complete cyclic changes,per unit of time,for which the input is rated.APTQ
Input Frequency Rating:
47.0 hertz single operating power rqmt and 63.0 hertz single operating power rqmt
MRC:
The ambient temperature range at which the item is designed to operate.AYNH
Operating Ambient Tempurature Range:
-0.0/+71.0 degrees celsius
MRC:
The number of output control(s) provided.BGHX
Output Control Quantity:
3 multiple power outputs w/identical ratings
MRC:
Indicates the type of output control provided.BGHY
Output Control Type:
Coarse voltage adjustment multiple power outputs w/identical ratings and current limit multiple power outputs w/identical ratings and switch multiple power outputs w/identical ratings and voltage adjustment multiple power outputs w/identical ratings
MRC:
The number of power units provided.BGQF
Power Unit Quantity:
2
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Dc ammeter and dc voltmeter and emi filter and over temperature protection and over voltage protector and remote control and remote error sensing capability and voltage adjustment and function switch
MRC:
The output current rating at which the item is designed to operate.CWGH
Output Current Rating:
12.5 dc amperes multiple power outputs w/identical ratings and 21.5 dc amperes multiple power outputs w/identical ratings
MRC:
Indicates the location of the output control(s).CWHC
Output Control Location:
Front panel multiple power outputs w/identical ratings
MRC:
The number of electrical output connections on the item.CWHF
Output Connection Quantity:
2 multiple power outputs w/identical ratings
MRC:
Indicates the type of electrical output connection.CWHJ
Output Connection Type:
Bus (bar) conductor multiple power outputs w/identical ratings
MRC:
The amount of input current for which the item is rated.CWHM
Input Current Rating:
18.0 ac amperes single operating power rqmt
MRC:
Indicates the type of electrical input connection.CWHQ
Input Connection Type:
Terminal strip single operating power rqmt
MRC:
The number of electrical input connections on the item.CWHT
Input Connection Quantity:
3 single operating power rqmt
MRC:
Indicates the type of design provided for ventilation of the item.CWKG
Ventilation Design Type:
Single fan
MRC:
The program(s) for which the power supply is design compatible.CWWJ
Program Compatibility:
Ieee-488 compatible
MRC:
The power supply operational efficiency when connected to an alternate current power line.CWWY
Power Supply Efficiency Line:
65.0
MRC:
An indication of the nuclear hardness criticality of the item.NHCF
Nuclear Hardness Critical Feature:
Nonhardened
MRC:
The measured weight of the actual container(s) or supporting device(s) which is in direct contact with the item and its contents.SUWT
Unit Of Issue Weight:
73.75 pounds