MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
2
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
Indicates the type of intake connection included on the item.AAYU
Intake Connection Type:
Threaded external
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
2
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded external
MRC:
Indicates the type of connection between the prime mover and the shaft.AAYX
Drive Connection Type:
Flexible coupled
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Water, fresh
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
525.0 gallons per minute
MRC:
The pressure of the media delivered by the item at maximum rated discharge capacity.AHYW
Discharge Pressure:
200.0 pounds per square inch gage
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The direction in which the pump shaft turns during operation.AHZD
Pump Rotation Direction:
Clockwise and counterclockwise
MRC:
The design of a centrifugal pump as determined by the direction of media flow with respect to the axis of the shaft.AHZE
Centrifugal Pump Design:
Radial flow
MRC:
The number of impellers incorporated in the centrifugal pump.AHZF
Centrifugal Pump Impeller Quantity:
2
MRC:
Indicates the type of suction produced by the impeller of the centrifugal pump.AHZG
Centrifugal Pump Impeller Suction Type:
Single
MRC:
Indicates the type of device used to control the output or capacity of an item.AHZP
Volume Control Type:
Push-pull
MRC:
Indicates the location of the control on the item.AHZQ
Control Location:
Left side
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
Threaded
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the discharge connection.ASAZ
Discharge Connection Thread Size And Series/type Designator:
2.500-7-1/2 nh
MRC:
Designates the thread diameter,series/type,and number of threads per measurement scale of the intake connection.ASWT
Intake Connection Thread Size And Series/type Designator:
4.500-4 nh