MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Oil
MRC:
The maximum rated capacity delivered by the item.AHYV
Maximum Discharge Flow Rate:
11.0 gallons per minute
MRC:
The speed of the item required to produce its rated capacity.AHYZ
Operating Speed At Rated Capacity:
1725.0 revolutions per minute
MRC:
The position in which the pumping element/s/ is designed to operate.AHZA
Pumping Element Operating Position:
Horizontal
MRC:
The direction in which the pump shaft turns during operation.AHZD
Pump Rotation Direction:
Counterclockwise
MRC:
The means by which the item is operated.AHZT
Operation Method:
Powered
MRC:
Indicates the type of drive shaft by the physical configuration,condition,and the like of the shaft end.AJAB
Drive Shaft Type:
D-type