TXT
묘사:
Radio Frequency Coil
MRC:
An indication that the level of probability that an item will operate without failure,at a specified rated capability,at a specified temperature,and for a specified period of time,has been established by testing random samples of production lot.AARG
Reliability Indicator:
Not established
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
1.125 inches
MRC:
An overall measurement taken at right angles to the length of an item,in distinction from thickness.ABMK
Overall Width:
0.437 inches
MRC:
The value(s) of inductance inherent in the item.ACYV
Inductance Rating:
1.10 microhenries single component single winding and 1.80 microhenries single component single winding
MRC:
Indicates the type of support on which the coil is wound.ACZP
Coil Form Type:
Hollow single component
MRC:
Indicates the type of drive provided for the adjustment device.ACZU
Adjustment Device Drive Type:
Slotted screw single component
MRC:
Indicates the type of inclosure provided to coat,cover,protect,or encase the item.AKNA
Inclosure Type:
Open
MRC:
The means of attaching the item.AXGY
Mounting Method:
Threaded bushing single group
MRC:
The means provided and number of adjustments included on the item.CTHD
Adjustment Method And Quantity:
1 adjustable core single component
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 tab, solder lug