부품 번호:
07aexxxxxxxa5axxxx01
부품 정보
Filled system; special dial
TXT
묘사:
Diff Fluid Flow Indicating Meter
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Flush
MRC:
The length of a straight line which passes through the center of a circular figure or body,and terminates at the circumference.ABMZ
Diameter:
7.500 inches
MRC:
The type of service with which the item is designed to be used.ACKL
Media For Which Designed:
Liquid
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Aluminum, cast
MRC:
A linear measurement from the surface to a specified inner point on an item,in distinction from height.AEJZ
Depth:
4.656 inches
MRC:
The name and number of parts supplied with the item which may be required for application.AKYD
Accessory Components And Quantity:
Stainless steel sensor, 1, housing assembly, 1
MRC:
The general outside configuration of the case.ANRX
Case Shape:
Round
MRC:
An indication of the presentation range of the scale.ASPF
Scale Presentation Range:
30.61 to 110.18 range of numerical markings
MRC:
Indicates the type of pressure.AXAF
Pressure Type:
Low or high
MRC:
The hue or tint of the inscription(s) and/or that portion of the scale which surrounds the inscription on the scale.BGKZ
Scale Inscription/background Color:
White markings on black background
MRC:
The maximum differential pressure which the item is capable of withstanding without evidence of deformation or other damage.CPYY
Maximum Differential Pressure:
110.18 in. Water column
MRC:
An indication of whether or not a totalizing integrator register is included.CPZB
Totalizing Integrator Register:
Not included