부품 정보
Range 0 to 100 psi absolute; accuracy 0.1% f.S.; temp range -55 degrees c to 71 degrees c; operating accuracy +/- 0.3% f.S. Over pressure and temp range; maximum operating temp -62 degrees c to 85 degrees c; input voltage 28 vdc 80 ma; 6 month stabili type 0.15% f.S.; bracket slides on and is held in position by captive screws; 2 screw holes 0.180 to 0.183 diameter
TXT
묘사:
Pressure Transmitter
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
6.000 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Dc
MRC:
The number of mounting devices used as a means of attaching the item.ACUP
Mounting Device Quantity:
1
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.500 inches
MRC:
The means by which the item is actuated.AFLW
Actuation Method:
Pressure sensing element
MRC:
The number of contacts which provide electrical connection.AFRA
Contact Quantity:
10
MRC:
Indicates the type of contact(s) included on the item.AKSF
Contact Type:
Pin
MRC:
The value(s) of potential for which the item is rated.AMSE
Voltage Rating:
1.0 volts output and 9.0 volts output
MRC:
The number of electrical connections provided.ASKX
Electrical Connection Quantity:
1
MRC:
The name of the government agency or commercial organization controlling the electrical connection.ASKY
Electrical Connection Controlling Agency:
Bendix
MRC:
The identifying number assigned by the government agency or commercial organization controlling the electrical connection.ASKZ
Electrical Connection Identifying Number:
Ptih-12-10p or equiv. Or ms3112e12-10p
MRC:
The number of mechanical connections provided.ASSB
Mechanical Connection Quantity:
1
MRC:
Designates the thread size,diameter,or the like,of the mechanical connection.ASSC
Mechanical Connection Size:
7/16-20 unf male per ms33656-e4
MRC:
Indicates the type of mechanical connection/s/ provided.ASSD
Mechanical Connection Type:
External thread and thread
MRC:
The means of attaching the item.AXGY
Mounting Method:
Bracket
MRC:
The minimum to maximum value which the item is capable of measuring.BHMW
Measurement Range:
+0.0/+100.0 inches of pressure