부품 정보
Altered portion includes cutting leads to 18.000 in., strip back 0.250 in., and alter 1 lead end to include male conn. Ms27144-2 and other lead end to include term. Lug ms25036-150
MRC:
The direction of the thread when viewed axially. a right-hand thread winds in a clockwise direction while a left-hand thread winds in a counterclockwise direction.AAJF
Thread Direction:
Right-hand 1st end
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
200.0 degrees fahrenheit single response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
G4 gasket sea (boss) 1st end
MRC:
The means used to control the operation of the valve.AQLR
Valve Operation Method:
Solenoid
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded internal boss 1st end
MRC:
The maximum pressure at which the item is rated for operation.CQGM
Maximum Operating Pressure:
3000.0 pounds per square inch single response
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.250 inches 1st end
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
12.0 dc
MRC:
The type of media for which the item is designed.MEDA
Media For Which Designed:
Hydraulic fluid, phosphate-ester base single response
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Nptf 1st end