TXT
				
				
					묘사:
				
				
					Electromagnetic Relay				
			 
			
										
					
						MRC:
						The distance measured in a straight line from the bottom to the top of an item.ABKW
					 
					
						Overall Height:
					
					
						0.265 inches 					
				 
							
					
						MRC:
						A measurement of the longest straight line across a circular cross-sectional plane.ADAV
					 
					
						Overall Diameter:
					
					
						0.370 inches 					
				 
							
					
						MRC:
						The environmental elements or conditions that an item is designed or protected to resist or withstand satisfactorily.ADZC
					 
					
						Environmental Protection:
					
					
						Hermetic					
				 
							
					
						MRC:
						The number of coils included on the item.APCN
					 
					
						Coil Quantity:
					
					
						1					
				 
							
					
						MRC:
						The measured opposition to the flow of direct current offered by the item winding.APNA
					 
					
						Winding Dc Resistance Rating:
					
					
						1017.0 ohms  single winding and 1243.0 ohms  single winding					
				 
							
					
						MRC:
						Indicates the type of duty provided.APNP
					 
					
						Duty Type:
					
					
						Continuous					
				 
							
					
						MRC:
						Indicates the type and number of facilities by which the item is mounted.AXHR
					 
					
						Mounting Facility Type And Quantity:
					
					
						8 plug-in terminal single mounting facility					
				 
							
					
						MRC:
						The general configuration and relative position of the facilities provided for mounting the item.CQYJ
					 
					
						Mounting Facility Pattern:
					
					
						Ciruclar single mounting facility					
				 
							
					
						MRC:
						The amount and type of voltage required at designated temperature to be applied to the input or energizing element of the item to ensure normal operation of the switching elements.CSXF
					 
					
						Operating Voltage Rating And Type At Specificationified Temp:
					
					
						20.0 volts dc 125 degrees celsius single winding					
				 
							
					
						MRC:
						The lowest net amount of the specified energizing electrical characteristic necessary for the normal functioning of the relay. the net value being the difference between multiple or opposed input elements during normal operation.CTCN
					 
					
						Minimum Differential Electrical Operating Rating:
					
					
						20.0 volts					
				 
							
					
						MRC:
						Indicates the type and number of terminals for providing electrical connection.TTQY
					 
					
						Terminal Type And Quantity:
					
					
						8 pin contacts