TXT
묘사:
Quick Disconne Coupling Assembly
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.AAJD
Thread Class:
3a first fluid end connection
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.191 inches
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the end.ACLT
Second End Style Designator (non-core):
Err-090
MRC:
The length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.ACMP
Second End Outside Diameter Tube Accommodated:
0.500 inches
MRC:
A numeric-alpha designator indicating the pitch diameter tolerance and an external or internal thread.ACMR
Second End Thread Class:
3a
MRC:
The means by which mechanical action completely engages or disengages a mating quick disconnect part.ADLN
Quick Disconnect Method:
Quick lead thread all ends
MRC:
A narrative description of the type of end connection.ADMB
Second Fluid End Connection Type:
Threaded external tube
MRC:
The style designation indicating the configuration that most nearly corresponds to the shape of the mounting flange.ADMD
Mounting Flange Shape Style (non-core):
Err-090
MRC:
The length of a straight line which passes through the center of a mounting flange,and terminates at the outside circumference.ADME
Mounting Flange Outside Diameter:
2.005 inches
MRC:
The number of bolt holes in the mounting flange.ADML
Mounting Flange Bolt Hole Quantity:
6
MRC:
The length of a straight line which passes through the center of a mounting flange bolt hole,and terminates at the circumference.ADMM
Mounting Flange Bolt Hole Diameter:
0.201 inches
MRC:
The length of a straight line which passes through the center of a mounting flange bolt circle,and terminates at the circumference.ADMN
Mounting Flange Bolt Circle Diameter:
1.687 inches
MRC:
The distance from the bearing surface of the flange to the end of the leg portion of the item.ADMY
Distance From Mounting Flange To Fluid End:
1.501 inches
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
54.0 degrees celsius single response
MRC:
The maximum temperature at which the item is rated to operate for an extended period of time.AEHZ
Maximum Operating Temp:
71.1 degrees celsius 1st response
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the connection.AHNC
Connection Style:
Flared first fluid end connection
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external tube first fluid end connection
MRC:
Indicates the type of connection/s/.AWLS
Connection Type:
Threaded external tube second fluid end connection
MRC:
Those features,not otherwise specified,which may be required for proper functioning of the item.CBBL
Features Provided:
Self-sealing
MRC:
Indicates whether or not the second end is identical to the first end.CQBB
Second End Relationship With First End:
Not identical
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.750 inches first fluid end connection
MRC:
Indicates the location of the mounting flange on the item.CQKS
Mounting Flange Location:
First leg
MRC:
The angle of the end surface upon which the mated surface seats.CQRB
Seat Angle:
37.0 degrees
MRC:
The angle of the end surface upon which the mated surface seats.CRCN
Second End Seat Angle:
37.0 degrees
MRC:
The designation which is used for the purpose of general identification of the nominal thread size.CRNB
Second End Thread Size:
0.750 inches
MRC:
A designator distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.CRPF
Second End Thread Series Designator:
Unf
MRC:
A rating which expresses the degree of heat or cold as applied to the operation,or limitation of operation,for each type of service with which an item may be used.CRWH
Maximum Operating Tempurature And Media For Which Designed:
Err-070
MRC:
The nominal length of a straight line which passes through the center of the accommodated tube,and terminates at the outside circumference.CWFD
Outside Diameter Tube Accommodated:
0.500 inches first fluid end connection
MRC:
The chemical compound or mechanical mixture properties of which the item is fabricated.MATT
Material:
Aluminum alloy
MRC:
The metallic,nonmetallic,and/or chemical properties with which the item is plated,dipped,and/or coated.the treatment is designed to protect the surface(s) and cannot be wiped off.SFTT
Surface Treatment:
Anodize
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the item.STYL
Style Designator:
Coupling assembly
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf first fluid end connection
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unf second fluid end connection