부품 번호 0111-15CURVE3

Circuit Breaker

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 64.8 and 87.48 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
0111-15curve3
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
006178122
NSN
국가 주식 번호:
5925-00-617-8122 5925006178122
TXT
묘사:
Circuit Breaker
INC
INC
아이템 이름 코드:
00136
MRC:
The style designation indicating the configuration that most nearly corresponds to the appearance of the body.AAQL
Body Style:
Single pole type
MRC:
A measurement of the longest dimension of the body,in distinction from width.ADAQ
Body Length:
Between 3.209 inches and 3.229 inches
MRC:
A measurement taken at right angles to the length of the body,in distinction from thickness.ADAT
Body Width:
Between 1.459 inches and 1.479 inches
MRC:
A measurement from the bottom to the top of the body,in distinction from depth.ADAU
Body Height:
Between 2.630 inches and 2.650 inches
MRC:
The element,compound,or mixture of which the case is fabricated,excluding any surface treatment.ADTV
Case Material:
Plastic
MRC:
The center to center distance between terminals parallel to the length of the item.AEBP
Center To Center Distance Between Terminals Parallel To Length:
Between 2.740 inches and 2.760 inches
MRC:
The length of a straight line which passes through the center of an unthreaded mounting hole,and terminates at the circumference.AEBV
Unthreaded Mounting Hole Diameter:
0.164 inches
MRC:
The distance between centerlines of mounting facilities parallel to the length of the item.AEBY
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.302 inches and 1.322 inches
MRC:
None.AJEC
Boss Height:
Between 0.115 inches and 0.135 inches
MRC:
The number of poles included in the item.AKPX
Pole Quantity:
1
MRC:
The means of quenching an arc.APNQ
Arc Quenching Method:
Magnetic blowout
MRC:
Indicates the type and number of facilities by which the item is mounted.AXHR
Mounting Facility Type And Quantity:
2 threaded hole and 2 unthreaded hole
MRC:
Indicates the type of storage space required for an item in order to provide the degree of protection necessary to maintain serviceability standards.BBRG
Storage Type:
General purpose warehouse
MRC:
The number of threads on the item per linear inch measured on a line parallel to the thread axis.CMLP
Thready Qty Per Inch (tpi):
32
MRC:
The maximum current load that each pole is rated to carry continuously.CPLM
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac single location
MRC:
Indicates the type and value of operating voltage for which each pole is designed to operate,expressed in volts.CPRF
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac single location
MRC:
Indicates the type and value of the maximum short circuit current that the item will successfully interrupt,per pole,at the specified rated voltage,expressed in amperes.CPRG
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac single location
MRC:
Indicates the type of electrical condition that will cause the device to trip.CPRH
Circuit Protection Type:
Overcurrent single location
MRC:
The means by which the trip mechanism is released.CPRJ
Trip Release Method:
Magnetic-hydraulic single location
MRC:
Denotes the type of trip release action.CPRL
Trip Release Characteristic:
Time delay single location
MRC:
The continuous current rating per pole at which the device must trip in a specified time,expressed in percent.CPRN
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 single location
MRC:
The means provided to reposition the mechanism so that the device is ready to function.CPRQ
Reset Method:
Manual
MRC:
Indicates the type of mechanism provided for tripping main contacts.CPRR
Main Contact Tripping Mechanism Type:
Trip free
MRC:
Indicates the type and number of actuators provided for manual control.CPRT
Manual Actuator Type And Quantity:
1 toggle
MRC:
Denotes the action imparted by actuator operation.CPRW
Actuator Function:
Trip-reset
MRC:
An indication of the designated position of the actuator.CPRX
Actuator Position Designation:
At pole one
MRC:
The basic internal electrical configuration of the trip mechanism.CPSM
Internal Trip Release Configuration:
Series trip single location
MRC:
A designation that is used for the purpose of general identification of the thread.CQJX
Thread Size:
0.138 inches
MRC:
The length of time,expressed in seconds,that an overload may exist before the device will trip at a specified continuous current.CQWN
Trip Delay Time In Seconds Per Rated Continuous Current:
0.320 at 200 pct single location and 0.950 at 200 pct single location
MRC:
Indicates the type of protection for which the inclosure is designed.CQXF
Inclosure Protection Type For Which Designed:
Shock resistant and vibration resistant
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0 single location
MRC:
A designation distinguishing one group of thread diameter-pitch combinations from another by the number of threads per measurement scale for a specific diameter.THSD
Thread Series Designator:
Unc
MRC:
Indicates the type and number of terminals for providing electrical connection.TTQY
Terminal Type And Quantity:
2 compression

{lang[cimilar]} Circuit Breakers

« Circuit Breakers {lang[catalog]}
지금 비교»
맑다 | 숨기다