TXT
묘사:
Rotary Compressor Unit
MRC:
The number of compressors incorporated in the unit.AAXG
Compressor Quantity:
1
MRC:
The percentage of time for which the item is designed to generate without degradation of rated capacity and discharge pressure.AAXJ
Duty Cycle In Percent:
100
MRC:
The media the machine is designed to compress.AAXK
Gas For Which Designed:
Air
MRC:
The rated capacity of gas delivered by the last stage of compression.AAXL
Discharge Flow Rate:
112.000 cubic feet per minute
MRC:
The gage pressure of gas delivered by the last stage of compression. referred to as condensing pressure for refrigeration compressors.AAXM
Discharge Pressure:
125.000 pounds per square inch gage
MRC:
The design of the system necessary to maintain the required operating temperature of an item and discharge temperature of the compressed gases.AAXP
Cooling System Design:
Mixed
MRC:
The cooling medium used to maintain the required operating temperature of the compressed gases.AAXQ
Compressed Gas Cooling Medium:
Air and oil
MRC:
The cooling medium used to maintain the required operating temperature of the compressor.AAXR
Compressor Cooling Medium:
Air and oil
MRC:
The cooling medium used to maintain the required operating temperature of the prime mover.AAXS
Prime Mover Cooling Medium:
Air
MRC:
The position of the gas cooling equipment whether between stages /intercooler/,after the last stage /aftercooler/,or both.AAXU
Gas Cooling Equipment Type:
Air type aftercooler
MRC:
The method by which a no load condition is obtained for starting the item.AAXV
Unloader Type:
Automatic and manual
MRC:
The power required to start and operate the item at the actual rated capacity,including all accessories.AAXW
Brake Horsepower Required:
30.000
MRC:
Indicates the type of mount utilized to support the item.AAXX
Mounting Type:
Base
MRC:
The mechanical action by which compression takes place.AAYB
Rotary Compressor Design:
Axial screw
MRC:
The number of stages incorporated in the item.AAYD
Stage Quantity:
1
MRC:
The speed of the compressor required to produce its rated capacity,expressed in revolutions per minute.AAYS
Compressor Speed At Rated Capacity In Rpm:
1800.0
MRC:
The number of intake connections included on the item.AAYT
Intake Connection Quantity:
1
MRC:
The number of discharge connections included on the item.AAYV
Discharge Connection Quantity:
1
MRC:
Indicates the type of discharge connection included on the item.AAYW
Discharge Connection Type:
Threaded female
MRC:
Indicates a device used to eliminate the noise of the intake or discharge of the item.AAZA
Silencer Type:
Inlet
MRC:
Indicates the type of prime mover included with the unit.AKDJ
Prime Mover Type:
Electric motor
MRC:
Indicates the type of control device provided.BDML
Control Device Type:
Automatic start-stop and constant speed and motor starter
MRC:
Indicates the type of safety device(s) provided.BPRZ
Safety Device Type:
High temperature shutdown switch and low pressure oil shutdown switch and relief valve
MRC:
Indicates the type and amount of electrical flow at which the item is designed to operate,expressed in amperes.CQJY
Current Type And Rating In Amps:
37.0 ac
MRC:
The total electrical voltage,expressed in volts,and the type of current whether alternating or direct.CSBH
Voltage In Volts And Current Type:
220.0 ac or 440.0 ac
MRC:
The degree of heat or cold as applied to the function of the item.CSFH
Tempurature Rating Per Function:
Not rated
MRC:
The brake power required to start and operate the item including all accessories at the actual rated capacity,expressed in unit of power.CXNT
Brake Power Required:
30.000 horsepower
MRC:
The number of alternating current phases.FAAZ
Phase:
Three
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
60.0