부품 번호 002426

Overvoltage Absorber

가격 및 가용성

이 NSN의 현재 가격 및 가용성에 대해 이 양식을 제출하십시오.
부품 번호:
양:
이메일 주소:
전화:
참조:
회사:
이름:

우리는 귀하의 정보를 누구에게도 공유하거나 판매하지 않습니다.
사생활 | 용어

All major credit cards accepted as well as gov. p-cards

이 제품의 과거 가격은 79.48 and 107.298 USD. 수량, 가용성, 상태, 리드 타임 및 품목 중단 가능성에 따라 최신 견적을 제공할 때까지 가격을 보장할 수 없습니다.

부품 번호
비무장화
수명
UOM
NIIN
부품 번호:
002426
비무장화:
No
수명:
N/A
측정 단위:
1 EA
NIIN:
005394168
NSN
국가 주식 번호:
5920-00-539-4168 5920005394168
TXT
묘사:
Overvoltage Absorber
INC
INC
아이템 이름 코드:
21899
MRC:
The number of terminals for providing electrical connection to the item.AARA
Terminal Quantity:
2
MRC:
Indicates the type of terminals for providing electrical connection to the item.AARB
Terminal Type:
Wire lead
MRC:
The dimension measured along the longitudinal axis with terminated points at the extreme ends of the item.ABHP
Overall Length:
4.500 inches
MRC:
Indicates the type of current whether alternating,direct,or both.ACDC
Current Type:
Ac
MRC:
A measurement of the longest straight line across a circular cross-sectional plane.ADAV
Overall Diameter:
1.875 inches
MRC:
The means of attaching the item.ADJH
Mounting Method:
Terminals, wire lead
MRC:
The pattern or arrangement that describes the mounting configuration of the item.ALGC
Mounting Configuration:
Two leads 1.500 in. Long 0.040 in. Diameter axially located for mounting in any position
MRC:
An indication of whether or not a polarization feature is included.ALPY
Polarization Feature:
Not included
MRC:
The electrical current rating,expressed in amperes.AMPS
Current Rating In Amps:
70.0
MRC:
The amount of current the item is designed to interrupt.AQAY
Current Interrupting Capacity:
50.0 kiloamperes
MRC:
An indication of whether or not a shunt capacitor is included.AQCT
Shunt Capacitor:
Not included
MRC:
The element,compound,or mixture of which the element is fabricated,excluding any surface treatment.AQCW
Element Material:
Silicon carbide
MRC:
The amount of current for which the absorber is rated.AQDK
Absorber Current Rating:
Between 60.000 amperes and 75.000 amperes
MRC:
The name of the item which is being protected.AQDN
Protected Item Name:
Integrated circuit
MRC:
The total electrical voltage.ELEC
Voltage In Volts:
330.0
MRC:
The cycles per second /hertz/ of the alternating current.FREQ
Frequency In Hertz:
40.0